Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
2.
Eur J Vasc Endovasc Surg ; 53(2): 229-236, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27890525

RESUMO

OBJECTIVE: To identify which deep anatomical anomalies can explain variable hemodynamic outcomes in patients with superficial reflux associated with primary deep axial reflux who underwent isolated superficial vein ablation without improvement. METHODS: This is a retrospective study of deep venous valve anomalies in patients who underwent superficial vein ablation for superficial and associated deep reflux. A group of 21 patients who were diagnosed with saphenous reflux associated with primary deep axial reflux, were submitted to great saphenous vein ablation. In 17 patients the deep reflux was not abolished. In this subgroup, surgical exploration of the deep valve was carried out using venotomy for possible valve repair. RESULTS: Among the 17 subgroup patients, four post-thrombotic lesions were discovered intra-operatively in four patients; they underwent different surgical procedures. In 13 of the subgroup patients, primary valve incompetence was confirmed intra-operatively. In 11 cases the leaflets were asymmetrical and in only two were they symmetrical. After valvuloplasty, deep reflux was abolished in all 13 patients. Clinical improvement was obtained in 12/13 patients (92%). It is noteworthy that abolition of deep reflux was associated with significant improvement in air plethysmography data as well as with improvement in clinical status measured on CEAP class, VCSS and the SF-36 questionnaire. CONCLUSION: Failure to correct deep axial reflux by superficial ablation in patients with superficial and associated primary deep axial reflux may be related to asymmetry in the leaflets of the incompetent deep venous valve.


Assuntos
Técnicas de Ablação , Hemodinâmica , Veia Safena/cirurgia , Insuficiência Venosa/cirurgia , Válvulas Venosas/anormalidades , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Pletismografia , Estudos Retrospectivos , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler , Insuficiência Venosa/diagnóstico , Insuficiência Venosa/fisiopatologia , Válvulas Venosas/fisiopatologia
5.
Phlebology ; 30(7): 462-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24920424

RESUMO

Venous obstruction at iliocaval level in both forms, primary and secondary, is a significant cause of severe chronic venous insufficiency. A new therapeutic approach to this pathology emerged with the introduction of stenting procedures that proved effective, leading to good long-term results. However, at present, the majority of implanted stents have been designed for arterial implant and this can pose a limit in particular districts. The purpose of this preliminary acute study was to verify the deliverability and safety of a new stent specially designed for venous-vessel implant. We assess the safety and deliverability of two braided, self-expanding, nickel-titanium stents (Jotec GmbH, Hechingen, Germany) specially designed for endovascular implant in veins. The two stents, despite being based on the same concept, have a different design: stent A presents a proximal tapering shape specially designed to reduce migration, while stent B does not. Both of them are enlarged at their distal extremity and present variable radial force the length of the stent itself, the said force becoming very high in the intermediate segment. Stents were implanted in the internal jugular vein of a sheep, showing optimal deliverability. The completion venography showed the migration of stent B into the right atrium. Stent A maintained its location, confirmed by intravascular ultrasound examination. No scaffolding effect was detected and an adequate adherence and adaptability to the vein wall was obtained. In conclusions, the stent A design matches the characteristics required by vein implants. Stability is achieved even where difficult anatomical conditions apply, such as in the jugular vein. Deployment is easy and precise in a given landing zone. Radial resistive force is very high, as required in specific vein districts, but is also associated with good flexibility. Following this preliminary acute report, further studies are required.


Assuntos
Desenho de Prótese , Stents , Insuficiência Venosa/cirurgia , Animais , Doença Crônica , Ovinos
6.
Int Angiol ; 33(3): 275-81, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24861564

RESUMO

AIM: Chronic venous disease (CVD) is the result of venous reflux, obstruction or a combination of both. So far, attempts to correlate venous hemodynamic measurements with symptoms and signs of CVD have produced poor to moderate results, probably because of lack of methods to quantitate obstruction and combine measurements of reflux and obstruction. Our hypothesis is that the combination of quantitative measurements of (a) overall reflux (superficial and deep) and (b) overall outflow resistance i.e. including the collateral circulation would provide a hemodynamic index that should be related to the severity of the disease. METHODS: Twenty-five limbs with chronic venous disease and 1 limb from a healthy volunteer (VCSS 0-13) were studied. The clinical CEAP classification was C0 in one limb, C1 in 2 limbs, C2 in 10 limbs, C3 in 3 limbs, C4 in 1 limb, C5 in 6 limbs and C6 in 3 limbs. Air-plethysmography was used to measure reflux (VFI in mL/s) when the subject changed position from horizontal to standing. Subsequently, with the subject horizontal and the foot elevated 15 cm, simultaneous recordings of pressure and volume were made on release of a proximal thigh cuff inflated to 70 mmHg. Pressure change was recorded with a needle in the foot and volume change with air-plethysmography. Flow (Q in mL/min) was calculated at intervals of 0.1 seconds from tangents on the volume outflow curve. Outflow resistance (R) was calculated at 0.1 second intervals by dividing pressure by the corresponding flow (R=P/Q). R increased markedly at pressures lower than 25 mmHg due to decrease in vein cross-sectional area, so resistance at 25 mmHg (R25) was used in this study. RESULTS: In a multivariable linear regression analysis with VCSS as the dependent variable, both VFI and R25 were independent predictors (P<0.001). Using the constant (0.595) and regression coefficients, the regression equation provided a Hemodynamic Index (HI) or estimated VCSS=0.595 + (VFI x 0.41) + (R25 x 98). Thus, HI could be calculated for every patient by substituting VFI and R25 in the equation. HI or calculated VCSS was linearly related to the observed VCSS (r=0.86). CONCLUSION: The results indicate that the combination of quantitative measurements of reflux and outflow resistance provide a hemodynamic index which is linearly related to the VCSS. These findings need to be confirmed in larger series.


Assuntos
Hemodinâmica , Extremidade Inferior/irrigação sanguínea , Varizes/fisiopatologia , Veias/fisiopatologia , Insuficiência Venosa/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Estudos de Casos e Controles , Doença Crônica , Circulação Colateral , Constrição Patológica , Humanos , Modelos Lineares , Análise Multivariada , Posicionamento do Paciente , Flebografia , Pletismografia , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Índice de Gravidade de Doença , Ultrassonografia de Intervenção , Varizes/diagnóstico , Resistência Vascular , Veias/diagnóstico por imagem , Insuficiência Venosa/diagnóstico
7.
Phlebology ; 27 Suppl 1: 178-86, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22312087

RESUMO

BACKGROUND: The possible role of the venous system in the pathogenesis of chronic neurodegenerative diseases has been hypothesized for decades. Quite recently, the description of a venous condition defined as chronic cerebrospinal venous insufficiency (CCSVI) and its strong association with multiple sclerosis (MS) has brought back the attention of the scientific community to the hypothesis of an aetiological or concomitant role of an altered venous function in the occurrence of this pathology. CCSVI is identified by sonographic criteria, thus the indication for its possible treatment is based on ultrasound findings. METHOD: We retrospectively examined 167 consecutive patients affected by clinically defined MS and CCSVI, identified by ultrasound assessment by the presence of at least two sonographic criteria. Ultrasonographic diagnosis of CCSVI was then integrated by venography and intravascular ultrasound examination (in 43 patients). Patients were all submitted to endovascular procedure (venoplasty). RESULTS: In 37% of cases there was no correspondence between the preoperative ultrasound assessment and the venographic findings. In the event of incongruity between venography and sonography, the intravascular ultrasound examination investigation, when performed, confirmed ultrasound findings in 42% of cases and venography results in 58%. At one month in 12% of cases ultrasound assessment showed the persistence of altered flux. In 67% of cases patients reported subjective amelioration, regarding non-specific symptoms. CONCLUSION: The pathophysiology of CCSVI is yet to be defined. The superior cava venous system is highly complex in terms of anatomy and possible anomalies, as well as its haemodynamic mechanisms. Further studies are required to define the parameters of diagnosis and treatment of CCSVI.


Assuntos
Veias Cerebrais , Procedimentos Endovasculares , Modelos Cardiovasculares , Esclerose Múltipla , Insuficiência Venosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Veias Cerebrais/diagnóstico por imagem , Veias Cerebrais/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Esclerose Múltipla/fisiopatologia , Esclerose Múltipla/terapia , Flebografia/métodos , Estudos Retrospectivos , Ultrassonografia , Insuficiência Venosa/diagnóstico por imagem , Insuficiência Venosa/etiologia , Insuficiência Venosa/fisiopatologia , Insuficiência Venosa/terapia
8.
Int Angiol ; 29(1): 64-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20224535

RESUMO

AIM: The advanced CEAP classification allows one to differentiate between isolated varicose veins (C2) and complicated varicose veins (C2, 3 - C2, 3, 4 - C2, 4 or C2, 3, 4, 5 etc) named (C2+). METHODS: The main objective of this study was to identify when using the advanced classification the prevalence of isolated varicose veins (C2) and complicated varicose veins (C2+) among patients consulting vascular specialists and to compare their symptomatic status and the data issued from the advanced CEAP including also the headings, Anatomy (A), Etiology (E) and Pathophysiology (P). RESULTS: 171 patients were evaluated, 100 in France and 71 in Italy. The prevalence of C2 and C2+ was the same in both countries: 64.4% in France and 63.3% in Italy. Also no difference was found in the prevalence of other descriptors: etiology, anatomy or pathophysiology. The time to complete the advanced form was less than 5 minutes for 65% of the investigators. CONCLUSION: The advanced CEAP is easy to use in daily pratice. We have the same prevalence of patients in France and in Italy, who consulted for isolated varicose veins or associated with other signs of chronic venous disorders.


Assuntos
Varizes/epidemiologia , Adulto , Idoso , Análise de Variância , Distribuição de Qui-Quadrado , Feminino , França/epidemiologia , Indicadores Básicos de Saúde , Inquéritos Epidemiológicos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Encaminhamento e Consulta , Índice de Gravidade de Doença , Terminologia como Assunto , Varizes/classificação , Varizes/complicações , Varizes/diagnóstico
9.
Phlebology ; 24(4): 151-6, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19620697

RESUMO

OBJECTIVES: To evaluate the effect of eccentric compression applied by a new crossed-tape technique on procedure-related pain occurrence after endovenous laser ablation (ELA) of the great saphenous vein (GSV). METHODS: From April 2005 to June 2006, 200 consecutive ELA procedures were randomized to receive (group A: 100) or not (group B: 100) an eccentric compression applied in the medial aspect of the thigh. Patients were scheduled for a seven-day examination to assess the level of pain experienced. Pain intensity was measured using a visual analogue scale giving a numerical grade from 0 (no pain) to 10 (worst pain ever). RESULTS: The intensity of postoperative pain was significantly reduced (P < 0.001) in the eccentric compression group as compared with the non-compression one. CONCLUSIONS: This technique of eccentric compression greatly reduces the intensity of postoperative pain after ELA of the GSV.


Assuntos
Terapia a Laser/métodos , Veia Safena/fisiopatologia , Meias de Compressão , Varizes/terapia , Insuficiência Venosa/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/diagnóstico , Coxa da Perna
10.
J Acoust Soc Am ; 114(1): 512-21, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12880062

RESUMO

Noise is an important theoretical constraint on the evolution of signal form and sensory performance. In order to determine environmental constraints on the communication of two freshwater gobies Padogobius martensii and Gobius nigricans, numerous noise spectra were measured from quiet areas and ones adjacent to waterfalls and rapids in two shallow stony streams. Propagation of goby sounds and waterfall noise was also measured. A quiet window around 100 Hz is present in many noise spectra from noisy locations. The window lies between two noise sources, a low-frequency one attributed to turbulence, and a high-frequency one (200-500 Hz) attributed to bubble noise from water breaking the surface. Ambient noise from a waterfall (frequencies below 1 kHz) attenuates as much as 30 dB between 1 and 2 m, after which values are variable without further attenuation (i.e., buried in the noise floor). Similarly, courtship sounds of P. martensii attenuate as much as 30 dB between 5 and 50 cm. Since gobies are known to court in noisy as well as quiet locations in these streams, their acoustic communication system (sounds and auditory system) must be able to cope with short-range propagation dictated by shallow depths and ambient noise in noisy locations.


Assuntos
Acústica , Comunicação Animal , Percepção Auditiva , Peixes , Água Doce , Ruído , Animais , Mascaramento Perceptivo , Espectrografia do Som , Vocalização Animal
11.
Artigo em Inglês | MEDLINE | ID: mdl-12665991

RESUMO

Two freshwater gobies Padogobius martensii and Gobius nigricans live in shallow (5-70 cm) stony streams, and males of both species produce courtship sounds. A previous study demonstrated high noise levels near waterfalls, a quiet window in the noise around 100 Hz at noisy locations, and extremely short-range propagation of noise and goby signals. To investigate the relationship of this acoustic environment to communication, we determined audiograms for both species and measured parameters of courtship sounds produced in the streams. We also deflated the swimbladder in P. martensii to determine its effect on frequency utilization in sound production and hearing. Both species are maximally sensitive at 100 Hz and produce low-frequency sounds with main energy from 70 to 100-150 Hz. Swimbladder deflation does not affect auditory threshold or dominant frequency of courtship sounds and has no or minor effects on sound amplitude. Therefore, both species utilize frequencies for hearing and sound production that fall within the low-frequency quiet region, and the equivalent relationship between auditory sensitivity and maximum ambient noise levels in both species further suggests that ambient noise shapes hearing sensitivity.


Assuntos
Sacos Aéreos/fisiologia , Potenciais Evocados Auditivos/fisiologia , Ruído , Perciformes/fisiologia , Vocalização Animal/fisiologia , Estimulação Acústica , Animais , Corte , Ecossistema , Água Doce , Audição , Humanos , Masculino , Perciformes/classificação , Limiar Sensorial/fisiologia , Comportamento Sexual Animal/fisiologia , Espectrografia do Som/métodos , Especificidade da Espécie , Estatística como Assunto , Processos Estocásticos , Movimentos da Água
13.
J Prosthet Dent ; 74(2): 127-32, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8537917

RESUMO

This study compared the influence of different methods of preimpression preparation on the quality of occlusal reproduction in irreversible hydrocolloid impressions. A total of 30 impressions of the lower dental arch of a patient were made with five different preimpression preparation procedures. Stone casts were made and analyzed. Critical comparison showed that the preimpression preparation influenced the quality of the occlusal surface of the cast. Fingerpainting the occlusal surface with fluid hydrocolloid before positioning the loaded impression tray, associated with use of a saliva ejector, reduced the incidence of macroscopic defects on the occlusal surface of the impressions.


Assuntos
Técnica de Moldagem Odontológica , Adulto , Alginatos , Análise de Variância , Feminino , Humanos , Modelos Dentários , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Propriedades de Superfície , Tensoativos , Agentes Molhantes
14.
J Mal Vasc ; 20(1): 48-50, 1995.
Artigo em Francês | MEDLINE | ID: mdl-7745359

RESUMO

We report a case of rupture of abdominal aortic aneurysm due to salmonella typhy infection. The patient had a first operation of prothesis graft which led to infective dehiscence. After a further operation of aortic over renal banding, the patient was in good health. The authors discuss the possibility to make an aortic banding combined with an extra-anatomic revascularization directly, instead of carrying out an in situ reconstruction.


Assuntos
Aneurisma Infectado/microbiologia , Aneurisma Roto/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Infecções por Salmonella/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias
15.
Minerva Stomatol ; 43(5): 207-13, 1994 May.
Artigo em Italiano | MEDLINE | ID: mdl-8072468

RESUMO

The authors examine the detail reproduction capacity and surface roughness of 11 commercially available materials [6 plasters (stones?), 2 epoxy resins and 3 polyurethane resins] indicated for the construction of working models with individually extractable dies. The study was performed in vitro according to the method outlined by the ADA in specification no. 19 relating to materials for elastomeric imprints. This specification describes the use of a steel test-block with which it is possible to prepare a master imprint in polyvinylsiloxane. This imprint allows the grooves of the test-block to be reproduced in the form of angular crest which represent the details to be reproduced. Both the master imprint and the samples to be tested were prepared according to the manufactures instructions. The study was performed in three stages: macroscopic analysis, microscopic analysis, profilometric analysis. The macroscopic analysis did not show any differences between the different materials tested. The microscopic analysis showed that when enlarged 40 times the resins revealed a smoother surface than the plasters. The surface quality of plasters was improved by using a hardening solution recommended by the manufacturer as an alternative to water, or by using spacer paint. The plaster materials gave excellent angular definition contrary to the epoxy and polyurethane resins. The use, where advised, of the hardening solution as an alternative to water did not alter this parameter. The electronic profilometer used for the profilometric analysis comprised a diamond sensor which, when run along the surface, recorded all roughness, translating it into chart form.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Revestimento para Fundição Odontológica/química , Técnica de Fundição Odontológica/instrumentação , Planejamento de Dentadura/instrumentação , Prótese Parcial Fixa , Modelos Dentários , Estudos de Avaliação como Assunto , Humanos , Teste de Materiais , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...